Bộ chuyển đổi J1939 sang Modbus TCP server/RTU Slave ICP DAS GW-7238D
The GW-7238D is a gateway that provides conversion between J1939 and Modbus TCP/RTU protocol. For J1939 network, the GW-7238D supports PDU1, PDU2, broadcast and destination specific type of J1939 messages. For Modbus TCP/RTU network, the GW-7238D is a Modbus TCP server / RTU slave to reply the request from Modbus TCP client / RTU master. Utility software is provided for users to configure J1939 and Modbus TCP/RTU setting in the GW-7238D. The application fields can be diesel power-train applications, In-Vehicle networks for trucks and buses, etc.
The following figure shows the application architecture for the GW-7238D

Applications
|
![]() |
Features
Module specs
-
RoHS Design
-
Provide PWR / ERR / J1939 / MODBUS indication LEDs
-
The built-in jumper to select 120 ohm terminal resister of CAN bus
-
Watchdog inside
J1939 Features
-
Transmission and reception of all types of J1939 messages, including PDU1, PDU2, broadcast and destination specific
-
J1939 Transport Protocol for transmission and reception of large messages (9 – 1785 bytes)
-
Supported BAM of Connection Management Message
-
Network addresses management
Modbus Features
-
Support RS-232, RS-485 and Ethernet interfaces
-
Support Modbus TCP server / RTU slave protocol
-
Communication support both Modbus TCP / RTU to J1939 at the same time
-
Configurable UART baud rates of 9600, 19200, 38400, 57600, 115200 bps
-
Allow Max 5 Modbus TCP clients to access GW-7238D simultaneously
-
Support Function Code 03 / 04 / 06 / 16 of Modbus functions for reading and writing J1939 Messages
Utility
-
Provide Modbus network configuration interface
-
Provide J1939 network configuration interface – Network Address / Device Name, etc
-
Provide J1939 Input / Output configuration interface
-
Provide Modbus monitoring interface


Comparison Table
ICP DAS Fieldbus Gateways Comparison Table:
|
Support Protocol
|
GW-7228
|
GW-7238D
|
GW-7433D
|
I-7231D
|
I-7232D
|
I-7241D
|
|
J1939
|
J1939
|
CANopen Master
|
CANopen Slave
|
CANopen Slave
|
DeviceNet Slave
|
|
|
Modbus
RTU lave |
Modbus
TCP Server RTU Slave |
Modbus
TCP server RTU Slave |
DCON
Master |
Modbus
RTU Master |
DCON
Master |
|
|
Comm. Interface
|
RS-232
RS-422 RS-485 |
RS-232
RS-485 Ethernet |
RS-232
RS-485 Ethernet |
RS-232
RS-485 |
RS-232
RS-485 |
RS-232
RS-485 |
|
Support Protocol
|
I-7242D
|
GW-7243D
|
GW-7434D
|
GW-7552
|
GW-7553
|
GW-7557
|
|
DeviceNet
Slave |
DeviceNet Slave
|
DeviceNet
Master |
PROFIBUS
DP-V0 Slave |
PROFIBUS
DP-V0 Slave |
PROFIBUS
DP-V0 Slave |
|
|
Modbus
RTU Master |
Modbus
TCP/RTU/ ASCII Master |
Modbus
TCP Server RTU Slave |
Modbus
RTU/ASCII Master/Slave |
Modbus TCP/
RTU/ASCII Master/Slave |
HART Master
|
|
|
Comm. Interface
|
RS-232
RS-485 |
RS-232
RS-485 Ethernet |
RS-232
RS-485 Ethernet |
RS-232
RS-422 RS-485 |
RS-232
Ethernet |
RS-232
|
|
Support Protocol
|
HART-710
|
GW-5492
|
GW-5493
|
|
HART Master
|
BACnet/IP Server
|
BACnet/IP Server
|
|
|
Modbus
RTU/ASCII Slave |
Modbus
RTU Master |
Modbus
TCP Client |
|
|
Comm. Interface
|
RS-232
RS-422 RS-485 |
RS-232
RS-485 Ethernet |
RS-232
Ethernet |
Hardware Specifications
|
Hardware
|
|
|
CPU
|
80186, 80 MHz or compatible
|
|
CAN Interface
|
|
|
Controller / Transceiver
|
NXP SJA1000T with 16 MHz clock / NXP 82C250
|
|
Channel number
|
1
|
|
Connector
|
5-pin screwed terminal block (CAN_L, CAN_H, N/A for others)
|
|
Baud Rate (bps)
|
250 k
|
|
Isolation
|
1000 VDC for DC-to-DC, 2500 Vrms for photo-couple
|
|
Terminator Resistor
|
Jumper for 120 Ω terminator resistor
|
|
Specification / Protocol
|
ISO-11898-2, CAN 2.0A and CAN 2.0B / J1939
|
|
UART Interface
|
|
|
COM 1 / Protocol
|
RS-232 / Modbus RTU
|
|
COM 1 Connector
|
5-pin screwed terminal block (TxD, RxD, RTS, CTS, GND)
|
|
COM 2 / Protocol
|
RS-485 (Self-turner inside) / Modbus RTU
|
|
COM 2 Connector
|
2-pin screwed terminal block (DATA+, DATA-)
|
|
Ethernet Interface
|
|
|
Controller
|
10/100Base-TX Ethernet Controller (Auto-negotiating, Auto_MDIX)
|
|
Connector / Protocol
|
RJ-45 with LED indicator / Modbus TCP
|
|
LED
|
|
|
Round LED
|
PWR / J1939 / MODBUS / ERR
|
|
Power
|
|
|
Power supply
|
Unregulated +10 ~ +30 VDC
|
|
Protection
|
Power reverse polarity protection, Over-voltage brown-out protection
|
|
Power Consumption
|
2 W
|
|
Mechanism
|
|
|
Installation
|
DIN-Rail
|
|
Dimensions
|
122mm x 72mm x 33mm (L x W x H)
|
|
Environment
|
|
|
Operating Temp.
|
-25 ~ 75 ℃
|
|
Storage Temp.
|
-30 ~ 80 ℃
|
|
Humidity
|
10 ~ 90% RH, non-condensing
|
Ordering Information
|
GW-7238D CR
|
J1939 to Modbus TCP Server / RTU Slave Gateway included CA-0910 cable(RoHS) |
Optional Accessories
| CA-0910-C | 9-pin Female D-sub & 3-wire CAN bus cable (1M) |
| SG-770 | 7/14 channel Surge Protector |
| 4PCD-002 | EMI Ferrite Split/Snap-On Core |
| M12A-5P-IP68 | Field-Installation A-coded 5-pin Female |