Module RS-485 DCON 10 kênh đầu vào cặp nhiệt Thermocouple ICP DAS I-7018Z
Features
- 10-channel Analog Input
- Temperature Output Consistency
- Stable Temperature Output in the Field
- Current, Voltage and Thermocouple Input
- Overvoltage Protection of up to 240 Vrms
- Individual Channel Configuration
- Open Thermocouple Detection
- 4 kV ESD Protection
- 3000 VDC Intra-module Isolation
- Dual Watchdog
- Wide Operating Temperature Range: -25 to +75°C
Introduction
The I-7018Z/M-7018Z is a 10-channel universal Analog Input module with an RS-485 interface that is especially designed for extremely accurate thermocouple measurement and features automatic cold-junction compensation for each channel to ensure temperature output consistency and stable temperature output in the field. The innovative design of the enhanced model ensures that thermocouple measurement is more accurate than with the earlier design. Besides the thermocouple inputs, the I-7018Z/M-7018Z also supports voltage and current input. The voltage input range can be from +/-15 mV to +/-2.5 V. Up to 10 different types of Analog Input can be connected to a single module. Overvoltage protection of up to 240 Vrms is provided. The module also features per-channel open wire detection for the thermocouple and +4 ~ +20 mA input channels. The M-7018Z provides additional support for both the Modbus RTU and DCON protocols, which can be configured via software, and all hardware specifications are the same as the I-7018Z.
Application
- Building Automation
- Factory Automation
- Machine Automation
- Remote Maintenance
- Remote Diagnosis
- Testing Equipment
I/O Specification
Models | I-7018Z | M-7018Z | |
Analog Input | |||
Channels | 10 | ||
Wiring | Differential | ||
Sensor Types | Thermocouple | J, K, T, E, R, S, B, N, C, L, M, LDIN43710 | |
Voltage | ±15 mV, ±50 mV, ±100 mV, ±500 mV, ±1 V, ±2.5 V | ||
Current | ±20 mA, 0 ~ 20 mA, 4 ~ 20 mA (requires an optional external 125 Ω resistor) | ||
Resolution | 16-bit | ||
Accuracy | ±0.1% of FSR | ||
Sampling Rate | 10 Hz (Total) | ||
Input Impedance | > 400 kΩ | ||
Common Voltage Protection | ±200 VDC | ||
Individual Channel Configuration | Yes | ||
Overvoltage Protection | 240 Vrms | ||
Open Wire Detection (for thermocouple only) |
Yes | ||
Temperature Output Consistency | Yes | ||
Stable Temperature Output in the Field | Yes |
System Specification
Models | I-7018Z | M-7018Z | |
Communication | |||
Interface | RS-485 | ||
Bias Resistor | No (Usually supplied by the RS-485 Master. Alternatively, add a tM-SG4 or SG-785.) | ||
Format | (N, 8, 1) (N, 8, 2) (E, 8, 1) (O, 8, 1) | ||
Baud Rate | 1200 to 115200 bps | ||
Protocol | DCON | Modbus RTU, DCON | |
Dual Watchdog | Yes, Module (1.6 Seconds), Communication (Programmable) | ||
LED Indicator/Display | |||
System LED Indicator | Yes, 1 as Power/Communication Indicator | ||
I/O LED Indicator | – | ||
7-Segment LED Display | – | ||
Isolation | |||
Intra-Module Isolation, Field-to-Logic | 3000 VDC | ||
EMS Protection | |||
ESD (IEC 61000-4-2) | ±4 kV Contact for each Terminal | ||
EFT (IEC 61000-4-4) | ±4 kV to Power | ||
Surge (IEC 61000-4-5) | ±0.5 kV for Power Line | ||
Power | |||
Reverse Polarity Protection | Yes | ||
Input Range | +10 ~ +30 VDC | ||
Consumption | 1.0 W | ||
Mechanical | |||
Dimensions (L x W x H) | M-7018Z | 116 mm x 73 mm x 35 mm | |
DB-1820 | 78 mm x 65 mm x 22 mm | ||
DN-1822 | 103 mm x 96 mm x 27 mm | ||
Installation | DIN-Rail or Wall Mounting | ||
Environment | |||
Operating Temperature | -25 to +75°C | ||
Storage Temperature | -40 to +85°C | ||
Humidity | 10 to 95% RH, Non-condensing |
Ordering information
I-7018Z-G/S CR | 10-channel Thermocouple Input Module using the DCON Protocol (Gray Cover) (RoHS) Includes an I-7018Z Module and a DB-1820 Daughterboard. |
I-7018Z-G/S2 CR | 10-channel Thermocouple Input Module using the DCON Protocol (Gray Cover) (RoHS) Includes an I-7018Z Module, a DN-1822 Daughterboard and a CD-2518D 1.8 m Cable. |
M-7018Z-G/S CR | 10-channel Thermocouple Input Module using the DCON and Modbus Protocols (Gray Cover) (RoHS) Includes an M-7018Z Module and a DB-1820 Daughterboard. |
M-7018Z-G/S2 CR | 10-channel Thermocouple Input Module using the DCON and Modbus Protocols (Gray Cover) (RoHS) Includes an M-7018Z Module, a DN-1822 Daughterboard and a CD-2518D 1.8 m Cable. |
|
|