Bộ chuyển đổi Modbus TCP/IP sang HART ICP DAS HRT-711
The HRT-711 Gateway is specially designed for the master device of HART protocol. It allows the Modbus master to access the HART devices. These HART devices may be a transmitter, an actuator and so forth. In addition, we also provide the utility software for users to configure the HRT-711. By using this module, users can integrate their HART devices into Modbus network easily.

Application
-
Industrial Automation
-
Factory Automation
-
Process Automation
-
Etc…
Features
-
Support HART Short/Long frame
-
Support HART Burst mode
-
Allow two HART Masters
-
Working in point-to-point or multi-drop HART mode
-
Connecting up to 15 HART modules
-
Support Modbus TCP/UDP server
-
Support Modbus Slave mode
-
Support firmware update via Com Port
-
Support on-line replacement of HART devices
-
Support acquire Long Frame Address automatically
-
Provide LED indicators
-
Built-in Watchdog
-
Mountable on DIN Rail
Utility
- Provide the system and communication configuration of HRT-711
- Provide the Modbus address table for HART command data
- Provide the diagnostic information of HRT-711 module and HART device
- Provide send / receive HART command to access HART device
- Provide “Load/Save” module configuration file to apply to other HRT-711 quickly
Modbus Support
Support the following Modbus commands.
| Code | Name | Description |
| 01 | Read Coil Status | Read the ON/OFF status of discrete outputs in the slave |
| 02 | Read Input Status | Read the ON/OFF status of discrete inputs in the slave |
| 03 | Read Holding Registers | Read the binary contents of holding registers in the slave |
| 04 | Read Input Registers | Read the binary contents of input registers in the slave |
| 05 | Force Single Coil | Write a single output to either ON or OFF in the slave |
| 06 | Preset Single Register | Write an integer value into a single register in the slave |
| 15 | Force Multi. Coils | Write each coil in the sequence of coils to either ON or OFF in the slave |
| 16 | Preset Multi. Registers | Write a block of contiguous registers in the slave |
Hardware Specification
| Ethernet Interface | |
| Controller | 10/100Base-TX Ethernet Controller (Auto-negotiating, Auto_MDIX) |
| Connector | RJ-45 x 1 (LED indicators) |
| UART Interface (For Configuration) | |
| COM Port | RS-232(3 wires) |
| Connector | 3-pin screwed terminal block |
| HART Interface | |
| HART Channel | 1 |
| HART Interface | 2-pin screwed terminal block |
| HART Device | 2-wired or 4-wired HART devices |
| HART Topology | Point to Point or Multi-Drop |
| HART Data | Only Digital Data |
| HART Frame Type | Short and Long Frame |
| Burst Mode | Supported |
| Max. HART Device | 15 |
| Loop Resistor | 250 Ω resistor by Jumper |
| Isolation | UL1577 Spec. |
| Power | |
| Power supply | Unregulated +10 ~ +30 VDC |
| Protection | Power reverse polarity protection, Over-voltage brown-out protection |
| Power Consumption | 1 W |
| Mechanism | |
| Installation | DIN-Rail or Wall Mounting |
| Dimensions | 72 mm x 35 mm x 121 mm (W x L x H) Detail |
| Environment | |
| Operating Temp. | -25 ℃ ~ +75 ℃ |
| Storage Temp. | -30 ℃ ~ +85 ℃ |
| Humidity | 5% ~ 95% RH, non-condensing |
Ordering Information
|
HRT-711 CR
|
Modbus TCP/UDP to HART Gateway (RoHS)
|