Bộ chuyển đổi Modbus RTU/ASCII sang HART ICP DAS HRT-310
The HRT-710 / HRT-310 Gateway is specially designed for the master dhfdhjnjuevice of HART protocol. It allows the Modbus master to access the HART devices. These HART devices may be a transmitter, an actuator and so forth. In addition, we also provide the software utility, HG_Tool, for module configuration and HART device diagnosis. By using these modules, users can integrate their HART devices into Modbus network easily and quickly.

Application
-
Industrial Automation
-
Factory Automation
-
Process Automation
-
Etc…

HRT-710 / HRT-310, a HART master to Modbus slave gateway, is applied to integrate the information from these HART flow meters into the customer’s HMI system. Through the HRT-710 / HRT-310, all of the HART flow meters will be regarded as Modbus slave devices and the HMI system can use the built-in Modbus RTU communication to access these HART flow meters easily.

More than 250 HART device information needs to be integrated to surveillance center. In PC side, uses 3 pieces of PCI cards (VXC-148U, for 24 channels RS-485 expansion). I-2542A and I-2542B (RS-485 to Fiber) are used in every RS-485 channel to extend RS-485 communication distance. There are about 20 pieces of HRT-710 modules used in every RS-485 channel with the different station ID. Through the structure, SCADA or HMI system can integrate all HART device information via Modbus protocol easily and quickly.
Features
- Support HART Short/Long frame
- Support HART Burst mode
- Allow two HART Masters
- Working in point-to-point or multi-drop HART mode
- Connecting up to 15 HART modules
- Support Modbus RTU and ASCII format
- Support Modbus Slave mode
- Support firmware update via Com Port. (FW_v1.2 and HW_v1.2)
- Support on-line replacement of HART devices. (FW_v1.5)
- Support acquire Long Frame Address automatically (FW_v1.5)
- Isolated COM Port : RS-232/422/485
- Provide LED indicators
- Built-in Watchdog
- DIN Rail or Wall Mounting
|
|
HRT-710 | HRT-310 |
| Din Rail Installation | Horizontal | Upright |
| HART Signal | Standard | Enhanced send/receive signal (For long distance comm.) |
| Loop Power | No | Support (module provides +30V output) |
| Built-In Resistor | 250 Ohm (1/4W) | 250 Ohm (1W) |
Utility
- Provide the system and communication configuration of HRT-710 / HRT-310
- Provide the Modbus address table for HART command data
- Provide the diagnostic information of HRT-710 / HRT-310 module and HART device
- Provide send / receive HART command to access HART device
- Provide “Load/Save” module configuration file to apply to other HRT-710 / HRT-310 quickly

Modbus Support
Support the following Modbus commands.
|
Code
|
Name
|
Description
|
|
01
|
Read Coil Status
|
Read the ON/OFF status of discrete outputs in the slave
|
|
02
|
Read Input Status
|
Read the ON/OFF status of discrete inputs in the slave
|
|
03
|
Read Holding Registers
|
Read the binary contents of holding registers in the slave
|
|
04
|
Read Input Registers
|
Read the binary contents of input registers in the slave
|
|
05
|
Force Single Coil
|
Write a single output to either ON or OFF in the slave
|
|
06
|
Preset Single Register
|
Write an integer value into a single register in the slave
|
|
15
|
Force Multi. Coils
|
Write each coil in the sequence of coils to either ON or OFF in the slave
|
|
16
|
Preset Multi. Registers
|
Write a block of contiguous registers in the slave
|
Hardware Specification
| Model Name | HRT-710 | HRT-310 |
| UART Interface | ||
| COM Port | RS-232(3 wires) / RS-422 / RS-485 | |
| Baud Rate (bps) | 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 | |
| Protocol | Modbus RTU / Modbus ASCII | |
| Connector | 9-pin screwed terminal block | 4-pin screwed terminal block |
| HART Interface | ||
| HART Channel | 1 | |
| HART Interface | 2-pin screwed terminal block | |
| HART Device | 2-wired or 4-wired HART devices | |
| HART Topology | Point to Point or Multi-Drop | |
| HART Data | Only Digital Data | |
| HART Frame Type | Short and Long Frame | |
| Burst Mode | Supported | |
| Max. HART Device | 15 | |
| Isolation | UL1577 Spec. | |
| Loop Resistor | 250 Ω (1/4W) by Jumper | 250 Ω (1W) by Dip-Switch |
| Loop Power | No | Yes (module provides +30V output) |
| Power | ||
| Power supply | Unregulated +10 ~ +30 VDC | |
| Protection | Power reverse polarity protection, Over-voltage brown-out protection | |
| Power Consumption | 1 W | 3.5W (Max.) |
| Mechanism | ||
| Installation | DIN-Rail or Wall Mounting (Horizontal) | DIN-Rail (Upright) |
| Dimensions | 72 mm x 35 mm x 121 mm (W x L x H) Detail | 25 mm x 116 mm x 120 mm (W x L x H) |
| Environment | ||
| Operating Temp. | -25 ℃ ~ +75 ℃ | |
| Storage Temp. | -30 ℃ ~ +80 ℃ | |
| Humidity | 5% ~ 95% RH, non-condensing | |
Ordering Information
|
HRT-710 CR
|
Modbus RTU/ASCII to HART Gateway (RoHS)
|
|
HRT-310 CR
|
Modbus RTU/ASCII to HART Gateway (Upright) (RoHS)
|