Bộ chuyển đổi PROFINET sang Modbus RTU/ASCII ICP DAS GW-7662
The GW-7662 specially designed for PROFINET IO device. It allows PROFINET controller to access Modbus devices. These Modbus devices maybe a PLC, a sensor, ICPDAS M-7000 series modules and so forth. We also provide a utility software for users to configure GW-7662. By using this module, users can put their Modbus devices into PROFINET network easily.

Application
-
Industrial Automation
-
Factory Automation
-
Process Automation
-
Etc…
Features
- Protocol: PROFINET IO Device
- PROFINET Conformance Class B and RT Class 1
- Cyclic Time: 1ms (min)
- Generic GSDML File Provided (Version 2.25)
- Max length of input/output data is 512/512 Bytes
- Support Modbus Master and Slave mode
- Support Modbus RTU and ASCII format
- Support several kinds of baud rate for COM1 from 1.2 to 460.8 kbps
- Provide LED indicators
- 4 kV Contact ESD protection for any terminal
- Wide range of power input (+10 to +30 VDC) and operating temperature (-25 to 75°C)
Utility
ICP DAS provides the PFN_Tool configuration utility to configure devices.
- Provide Modbus device setting
- Show diagnostic messages
- Provide Modbus test function
- Provide Communication Log of Modbus network

Modbus Support

Hardware Specifications
| Hardware | |
| CPU | 32-bit CPU Core |
| RAM/Flash/EEPROM | 32 MB / 4 MB / 8 KB |
| Watchdog | CPU built-in |
| ESD Protection | 4 kV class A |
| PROFINET Interface | |
| Protocol | PROFINET IO Device |
| Conformance Classes | Class B |
| Services | RTC, RTA, CL-RPC, DCP, LLDP, I&M |
| Cycle Time | 1 ms (min) |
| Ethernet Interface | |
| Controller | 10/100Base-TX Ethernet Controller (Auto-negotiating, Auto_MDIX) |
| Connector | RJ-45 x 2 (LED indicators) , Integrated 2-Port Switch |
| Services | ICMP, IGMP, ARP, DHCP, TELNET, TFTP, SNMP, VLAN Priority Tagging |
| UART Interface | |
| COM | RS-232/RS-422/RS-485 (can’t be used simultaneously) |
| COM Connector | 3-pin screwed terminal block (RxD, TxD, GND) 4-pin screwed terminal block (RxD+, RxD-, TxD+, TxD-) 2-pin screwed terminal block (DATA+, DATA-) |
| Baud Rate (bps) | 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400, 460800 |
| Data bit | 7, 8 |
| Stop bit | 1, 2 |
| Parity | None, Even, Odd |
| LED | |
| Round LED | AP LED, BOOT LED, ERR LED |
| Power | |
| Power supply | Unregulated +10 ~ +30 VDC |
| Protection | Power reverse polarity protection, Over-voltage brown-out protection |
| Power Consumption | 3.4 W |
| Mechanism | |
| Installation | DIN-Rail |
| Dimensions | 42 mm x 76 mm x 119 mm (W x L x H) |
| Environment | |
| Operating Temp. | -25 ~ 75 ℃ |
| Storage Temp. | -30 ~ 80 ℃ |
| Humidity | 10 ~ 90% RH, non-condensing |
Ordering Information
|
GW-7662 CR
|
PROFINET to Modbus RTU/ASCII Gateway (RoHS) |