Module 32 kênh đầu ra số DO ICP DAS F-8041
Features
- 32 digital output (sink) channels
- Safety value (Preset/Hold)
- Power-on(Initial) value
- Output channel LED indication
- RoHS compliance
- 3000 VDC isolation from output to backplane
- 3000 VDC isolation from output to frame ground
- Redundancy
- Fast redundant switching time (<100us)
Introduction
The F-8041 is a digital output module with 32 NPN channels. The output channel of F-8041 is a current sinking channel and can drive the load up to 0.5A current. The digital output channels offer LED to indicate digital output status. Moreover, the module offers 3000 VDC optical isolation between channels and backplane bus. If any high voltage or current damages the channels, the system (backplanes, other modules, and control unit) won’t be affected because the benefit of isolation.
Specifications
| Isolation | |
|---|---|
| Intra-module Isolation | 3000 VDC |
| EMS Protection | |
|---|---|
| EFT (IEC 61000-4-4) | Yes |
| ESD (IEC 61000-4-2) | Yes |
| LED Indicators | |
|---|---|
| Status | 1 x RUN, 1 x ACT, 1 x DUX and Communication (32 as channel 0~31 status) |
| Digital Output | |
|---|---|
| Channels | 32 (NPN) |
| Type | Sink, Open-collector |
| Max. Load Current | Singel channel: 2mA to 500 mA Maximum of total channels: 4.5 A |
| Power on Value | Yes |
| Safe Value | Yes (Preset/Hold) |
| I/O Expansion | |
|---|---|
| I/O Type | DN-DO-16DR-A, DN-DO-16DR-B, DN-DIO-M |
| Power | |
|---|---|
| Consumption | 2.1 W @ 24 VDC |
| Mechanical | |
|---|---|
| Dimensions (mm) | 30 x 85 x 115 |
| Weight | 300 g |
| Environmental | |
|---|---|
| Operating Temperature | -25 °C ~ +75 °C |
| Humidity | 5 ~ 95% RH, Non-condensing |
Ordering Information
| F-8041 CR | 32-ch Isolated DO Redundant Module (RoHS) |