Module RS-485 DCON 8 kênh đầu vào cặp nhiệt Thermocouple ICP DAS I-7018P
Features
- I-7018BL
- Open Thermocouple Detection
- I-7018P
- Additional Thermocouple Types, L and M
- 8-channel Differential or 6-channel Differential and 2-channel Single-ended Analog Input
- Current, Voltage or Thermocouple Input
- High Resolution: 16-bit
- 3000 VDC Intra-module Isolation
- Dual Watchdog
- RoHS Compliant
- Wide Operating Temperature Range: -25 to +75°C
Introduction
The I-7018P is an Analog Input module that features current and voltage input, as well as thermocouple input. The I-7018BL is a thermocouple input module. Both of the modules provide 8-channel differential or 6-channel differential and 2-channel single ended input that can be selected via a jumper, and all channels can be configured for the same input type. Note that an optional external 125 Ω resistor is required for current input. The modules also feature 3000 VDC intra-module isolation as well as ±35 VDC overvoltage protection. The I-7018BL provides thermocouple open wire detection and the I-7018P provides support for two additional thermocouple types, L and M.
Application
- Building Automation
- Factory Automation
- Machine Automation
- Remote Maintenance
- Remote Diagnosis
- Testing Equipment
I/O Specification
| Models | I-7018BL | I-7018P | |
| Analog Input | |||
| Channels | Differential and Single-ended, or Differential | ||
| Wiring | Differential | ||
| Sensor Types | Thermocouple | J, K, T, E, R, S, B, N, C | J, K, T, E, R, S, B, N, C, L, M |
| Voltage | – | ±15 mV, ±50 mV, ±100 mV, ±500 mV, ±1 V, ±2.5 V | |
| Current | – | ±20 mA (requires an optional external 125 Ω resistor) | |
| Resolution | 16-bit | ||
| Accuracy | 0.15% of FSR | 0.1% of FSR | |
| Sampling Rate | 10 Hz | ||
| Input Impedance | > 400 kΩ | ||
| Common Voltage Protection | ±15 VDC | ||
| Individual Channel Configuration | – | ||
| Overvoltage Protection | ±35 VDC | ±80 VDC | |
| Open Wire Detection (for thermocouple only) |
Yes | – | |
| Temperature Output Consistency | – | ||
| Stable Temperature Output in the Field | – | ||
Note: For highly-accurate thermocouple measurement, ICP DAS recommends selecting the I-7018Z/I-7019Z module,which features automatic cold-junction compensation for each channel, ensuring consistent and stable temperature output.
System Specification
| Models | I-7018BL | I-7018P |
| Communication | ||
| Interface | RS-485 | |
| Bias Resistor | No (Usually supplied by the RS-485 Master. Alternatively, add a tM-SG4 or SG-785.) | |
| Format | (N, 8, 1) (N, 8, 2) (E, 8, 1) (O, 8, 1) | |
| Baud Rate | 1200 to 115200 bps | |
| Protocol | DCON | |
| Dual Watchdog | Yes, Module (1.6 Seconds), Communication (Programmable) | |
| LED Indicator/Display | ||
| System LED Indicator | Yes, 1 as Power/Communication Indicator | |
| I/O LED Indicator | – | |
| 7-Segment LED Display | – | |
| Isolation | ||
| Intra-Module Isolation, Field-to-Logic | 3000 VDC | |
| EMS Protection | ||
| ESD (IEC 61000-4-2) | ±2 kV Contact for each Terminal | |
| EFT (IEC 61000-4-4) | ±4 kV to Power | |
| Surge (IEC 61000-4-5) | ±0.5 kV for Power Line | |
| Power | ||
| Reverse Polarity Protection | Yes | |
| Input Range | +10 ~ +30 VDC | |
| Consumption | 1.0 W | |
| Mechanical | ||
| Dimensions (L x W x H) | 123 mm x 72 mm x 35 mm | |
| Installation | DIN-Rail or Wall Mounting | |
| Environment | ||
| Operating Temperature | -25 to +75°C | |
| Storage Temperature | -40 to +85°C | |
| Humidity | 10 to 95% RH, Non-condensing | |
Ordering information
| I-7018BL CR | 8-channel Analog Input Module using the DCON Protocol (Blue Cover) (RoHS) |
| I-7018P CR | 8-channel Analog Input Module using the DCON Protocol (Blue Cover) (RoHS) |
| I-7018P-G CR | 8-channel Analog Input Module using the DCON Protocol (Gray Cover) (RoHS) |