Module 7 kênh đầu vào nhiệt độ RTD ICP DAS I-87015W
Features
- 7-channel RTD Input
- 3-wire RTD Lead Resistance Elimination for I-87015PW
- High Resolution: 16-bit
- Individual Channel Configuration
- Open Wire Detection
- Overvoltage Protection
- ±4 kV ESD Protection
- 3000 VDC Intra-module Isolation
- Wide Operating Temperature Range: -25 to +75°C
Introduction
The I-87015W is a 7-channel RTD input module that is used for measuring temperature using RTD. Each channel can be connected to different kinds of RTD sensor.
The I-87015PW is specifically designed for long-distance RTD measurement, and features automatic compensation for three-wire RTD so that it can measure accurately regardless of the length of the wires. The I-87015PW offers 7 channels, each of which can be connected to different kinds of RTD sensor.
Also, the I-87015W and I-87015PW are fully RoHS-compliant and features 4 kV ESD protection as well as 3000 VDC intra-module isolation.
Applications
- Building Automation
- Factory Automation
- Machine Automation
- Remote Maintenance
- Remote Diagnosis
- Testing Equipment
System Specifications
| Model | I-87015W | I-87015PW |
| Communication | ||
| Interface | RS-485 | |
| Format | N, 8, 1 | |
| Baud Rate | 1200 ~ 115200 bps | |
| Protocol | DCON | |
| Dual Watchdog | Yes, Module (1.6 Seconds), Communication (Programmable) | |
| LED Indicators/Display | ||
| System LED Indicator | 1 LED as Power/Communication Indicator | |
| I/O LED Indicator | 14 LEDs as High/Low Alarm Signals | |
| Isolation | ||
| Intra-module Isolation, Field-to-Logic | 3000 VDC | |
| EMS Protection | ||
| ESD (IEC 61000-4-2) | ±4 kV Contact for each Terminal | |
| ±8 kV Air for Random Point | ||
| Power | ||
| Power Consumption | 1.0 W Max. | |
| Mechanical | ||
| Dimensions (W x L x H) | 30 mm x 102 mm x 115 mm | |
| Environment | ||
| Operating Temperature | -25 ~ +75°C | |
| Storage Temperature | -40 ~ +85°C | |
| Humidity | 10 ~ 95% RH, Non-condensing | |
I/O Specifications
| Model | I-87015W | I-87015PW |
| Analog Input | ||
| Channels | 7 | |
| Wiring | 2/3-Wire | |
| Sensor Type | Pt100, Pt1000, Ni120, Cu50, Cu100, Cu1000 | |
| Resolution | 16-bit | |
| Accuracy | ±0.05% of FSR | |
| -3dB Bandwidth | 15.7 Hz | |
| Sampling Rate | 12 Hz (Total) | |
| Zero Drift | ±0.5 μV/°C | |
| Span Drift | ±20 ppm/°C | |
| Common Mode Rejection | 150 dB | |
| Normal Mode Rejection | 100 dB | |
| Input Impedance | >1 MΩ | |
| Individual Channel Configuration | Yes | |
| 3-wire RTD Lead Resistance Elimination | – | Yes |
| Resistance Measurement | 3.2 kΩ | |
| Open Wire Detection | Yes | |
| Overvoltage Protection | ±20 VDC | ±120 VDC |
NOTE: ICPDAS recommends selecting the I-87015PW for long-distance RTD Lines.
Ordering information
| I-87015W-G CR | 7-channel RTD Input Module (Gray Cover) (RoHS) |
| I-87015PW-G CR | 7-channel RTD Input Module with 3-wire Lead Resistance Elimination (Gray Cover) (RoHS) |
Accessories
| SG-770 CR | 7-channel Differential or 14-channel Single-ended Surge Protector (RoHS) |