Module RS-485 DCON 3-axis 32-bit Encoder Counter ICP DAS I-7083
Features
- 3-Axis Encoder Inputs
- 1 MHz Input Rate
- 32-bit Count Range
- Quadrant, Pulse/Dir, CW/CCW
- 2500 Vrms Optical Isolation
- Built-in Virtual Battery Backup for I-7083B(D)
- Dual Watchdog
- Wide Operating Temperature Range: -25 ~ +75°C
Introduction
The I-7083 and I-7083B are 3-axis high speed encoder modules. Each axis on the module can be independently confi gured as one of Quadrant, Pulse/Dir or CW/CCW input mode with a maximum input rate of 1 MHz. The high-end specifications of the I-7083/I-7083B and complete software support make it ideal for a wide range of applications in position measurement of motion systems working in industrial and laboratory environments. The I-7083B is an improved version of I-7083 with virtual battery backup function for counter value.
Application
- Building Automation
- Factory Automation
- Machine Automation
- Remote Maintenance
- Remote Diagnosis
- Testing Equipment
System Specification
| Model | I-7083 | I-7083B | I-7083D | I-7083BD |
| Communication | ||||
| Channels | RS-485 | |||
| Bias Resistor | No (Usually supplied by the RS-485 Master. Alternatively, add a tM-SG4 or SG-785.) | |||
| Format | N, 8, 1 | |||
| Baud Rate | 1200 to 115200 bps | |||
| Protocol | DCON | |||
| Dual Watchdog | Yes, Module (1.6 Seconds), Communication (Programmable) | |||
| LED Indicators/Display | ||||
| System LED Indicator | Yes, 1 as Power/Communication Indicator | |||
| I/O LED Indicators | – | |||
| 5-digit LED Display | – | Yes | ||
| Isolation | ||||
| Intra-module Isolation, Field-to-Logic | 3000 VDC | |||
| EMS Protection | ||||
| ESD (IEC 61000-4-2) | ±4 kV Contact for each Terminal | |||
| EFT (IEC 61000-4-4) | ±4 kV for Power Line | |||
| Surge (IEC 61000-4-5) | – | |||
| Power | ||||
| Reverse Polarity Protection | Yes | |||
| Input Range | +10 ~ +30 VDC (non-regulated) | |||
| Consumption | 1.5 W Max. | 1.7 W Max. | ||
| Mechanical | ||||
| Dimensions (L x W x H) | 123 mm x 72 mm x 35 mm | |||
| Installation | DIN-Rail or Wall Mounting | |||
| Environment | ||||
| Operating Temperature | -25 to +75°C | |||
| Storage Temperature | -30 to +80°C | |||
| Humidity | 10 to 90% RH, Non-condensing | |||
I/O Specification
| Model | I-7083 | I-7083D | I-7083B | I-7083BD |
| Digital Input | ||||
| Channels | 3-axis | |||
| Contact | Wet | |||
| Sink/Source (NPN/PNP) | Sink | |||
| Resolution | 32-bit | |||
| Max. Speed | 1 MHz | |||
| On Voltage Level | 5 V: +3.5 ~ +5 VDC 12 V with 1 kΩ External Resistor: +5 ~ +12 VDC 24 V with 2 kΩ External Resistor: +7 ~ +24 VDC |
|||
| Off Voltage Level | +2 VDC Max. | |||
| Encoder Mode | CW/CCW, Pulse/Dir, AB Phase | |||
| Virtual Battery Backup for Counter Value | – | Yes | ||
Ordering information
| I-7083-G CR | 3-axis, 32-bit Encoder Counter (Gray Cover) (RoHS) |
| I-7083D-G CR | 3-axis, 32-bit Encoder Counter with LED Display (Gray Cover) (RoHS) |
| I-7083B-G CR | 3-axis, 32-bit Encoder Counter (Gray Cover) (RoHS) |
| I-7083BD-G CR | 3-axis, 32-bit Encoder Counter with LED Display (Gray Cover) (RoHS) |