Phần mềm phát triển lập trình nhúng PAC ICP DAS Win-GRAF
What is a Win-GRAF?
Win-GRAF is a powerful SoftLogic development software and PLC-like SoftLogic package that supports IEC 61131-3 Standard Open PLC Languages running on Windows 7, 8, 10.
The Win-GRAF Runtime application can run on any ICP DAS PAC (Programmable Automation Controller) that supports the Win-GRAF, such as the WinPAC series WP-5238-CE7, WP-8×28-CE7, and WP-9xx8-CE7, or the touch panel ViewPAC series VP-x2x8-CE7, or the advanced CPU XPAC-CE6 series XP-8×38-CE6. Also, the Linux-based PAC RPAC-2658M is supported.
Using the Win-GRAF software with ICP DAS Win-GRAF PACs, the control/ monitor systems can easily implement the industrial level of data acquisition and logic control in various industrial fields.
Applications
- Data Acquisition System
- Factory Automation
- Building Automation
- Remote I/O system
- Wireless Monitor/Control System
- Motion Control System and so on

Ordering Information
| Win-GRAF Development Software | |
|---|---|
Win-GRAF Workbench
![]() |
Win-GRAF Workbench Software (Large I/O Tags) with one USB Dongle. |
Win-GRAF Workbench Features
►Support IEC 61131-3 Standard Open PLC Languages:
1. LD 2. FBD 3. SFC 4. ST 5. IL
►Event-Triggered Data Binding
A max. of 32 PACs can be used for data binding.

►Using ST Syntax in the FBD or LD Program

►Offline Simulation or Online Debugging/ Control/ Monitoring on PC
►Online Change
Replace the current running project to a new modified one without stopping the project.

►Recipe
Apply multi-recipes pre-defined in PC/Win-GRAF to PAC.
►Spy List
Show several selected variables in one Spy List window.
►Upload Source Code from a PAC to a PC
The user can set the password for the Win-GRAF project and download it with the source code to the PAC. Then, you can upload it anytime if the project file on the PC is damaged. Note that the user needs to enable the function to download the source code first.

Win-GRAF PAC Features
►Support eLogger HMI
eLogger is a free-of-charge and easy-to-use HMI software platform developed by ICP DAS. It can be used to design the Local HMI and the Web Server HMI for remotely controlling the PAC through a web browser on your PC or cell phone. All Win-GRAF PAC supports eLogger HMI.
Refer to Win-GRAF FAQ for more description about the Win-GRAF and eLogger HMI application

►Support Win-GRAF Redundant Solution
XP-8×38-CE6 supports the Win-GRAF redundant system to achieve more reliable engineering applications. When the running PAC crashes, the other PAC will take over after 3 seconds. The PAC can be automatically switched to the Active PAC or the Passive PAC. However, SCADA just needs to connect to a single Active IP.
If the PAC is damaged and needs to replace a new one, the user simply sets the rotary switch on the PAC and connects three cables (LAN1, LAN2, and Alive port). The Win-GRAF project will be automatically copied to the new PAC after power on.
For more description about the Win-GRAF redundant system, refer to Chapter 16 Redundancy of the Win-GRAF user manual.

►Modbus Master Protocol
- Multi-port Modbus RTU, ASCII Master, RS-232/485/422.
- Modbus TCP Master (Multiple connections).
- Connect other Modbus PLC, Modbus Master, Modbus I/O and Modbus devices.
►Modbus Slave Protocol
- Multi-port Modbus RTU Slave, RS-232/485/422.
- Modbus TCP Slave (Multiple connections).
- Connect PC/SCADA/HMI.
►Support DCON I/O
►Support Temperature/Humidity Modules
DL-100T485 and DL-100TM485.
►Support a Variety of I/O Modules
►Support File Access & Data Log
►Schedule-Control
►Support Retain Variables
All Win-GRAF PACs support retain variables. Suitable to retain the data changed quickly and frequently.
►Protect Application by Own Algorithm
Win-GRAF PAC is equipped with a unique 64-bit hardware serial number. It can be used to generate a license key to protect the software against illegal copies. Protect the Win-GRAF application by the user-defined algorithm. Even others copy the application to the same model PAC, as long as he cannot get the source code, cannot run the application correctly.

►Support VS 2008 Development
The Win-GRAF PACs support to use VS 2008 (VB.net, C#) to develop user own HMI and data management programs, and can exchange variables with the Win-GRAF control programs.

| Software | Win-GRAF | C++ | VS 2008 | ||
|---|---|---|---|---|---|
| Programming | Easy | Hard | Middle hard | ||
| SoftLogic | Yes | No | No | ||
| Debug | Easy | Hard | Middle hard | ||
| Data Management | Powerful, Middle hard Win-GRAF integrated with VS 2008 to achieve data management. |
Powerful, Hard | Powerful, Middle hard | ||
| Communication | Built-in Modbus TCP, RTU, ASCII, DCON, Data Binding | Hard coding | Hard coding | ||
| Program I/O | Easy | Hard | Hard | ||
The controller fully supports all five of the IEC61131-3 standard PLC languages:
1. Ladder diagram
2. Function block diagram
3. Sequential function chart
4. Structured text
5. Instruction list
It supports Modbus protocol and can link to distributed I/O modules with Modbus or DCON protocol via the RS-232/485 or Ethernet.
|
|
||||||||||||
|
Win-GRAF based XP-8000-CE6 series PAC
|
||||||||||||
| Model | OS | Pre-Installed Software |
CPU | System Memory | Non-Volatile Memory | Storage | VGA Resolution |
Ethernet Port |
USB Port | RS-232/ RS-485 |
I/O Slot | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| XP-8038-CE6 | Windows CE 6.0 | Win-RAF | x86 CPU,1.0 GHz, dual-core | 2 GB DDR3 SDRAM | 512 KB MRAM, 16 KB EEPROM | 32 GB Flash, 8 GB CF card |
640 x 480, 800 x 480, 800 x 600, 1024 x 768
|
2 | 4 | 5 | – | |
| XP-8138-CE6 | 4 | 1 | ||||||||||
| XP-8338-CE6 | 3 | |||||||||||
| XP-8738-CE6 | 7 | |||||||||||
|
|
|||||||||||
|
Win-GRAF based WP-9000 series PAC
|
|||||||||||
| Model | OS | Pre-Installed Software |
CPU | System Memory | Non-Volatile Memory | Storage | VGA Resolution |
Ethernet Port | USB Port | RS-232/ RS-485 |
I/O Slot |
|---|---|---|---|---|---|---|---|---|---|---|---|
| WP-9228-CE7 | Windows CE 7.0 | Win-GRAF | Cortex-A8, 1.0 GHz | 512 MB DDR3 SDRAM | 128 KB MRAM, 16 KB EEPROM | 256 MB Flash, 4 GB SD card | 800 x 600, 1024 x 768 | 2 | 2 | 4 | 2 |
| WP-9428-CE7 | 4 | ||||||||||
| WP-9828-CE7 | 8 | ||||||||||
|
|
||||||||||
|
Win-GRAF based WP-8000 series PAC
|
||||||||||
| Model | OS | Pre-Installed Software |
CPU | System Memory | Non-Volatile Memory | Storage | Ethernet Port | USB Port | RS-232/ RS-485 |
I/O Slot |
|---|---|---|---|---|---|---|---|---|---|---|
| WP-8128-CE7 | Windows CE 7.0 | Win-GRAF | Cortex-A8, 1.0 GHz | 512 MB DDR3 SDRAM | 512 KB MRAM, 16 KB EEPROM | 256 MB Flash, 4 GB microSD card | 2 | 2 | 2 | 1 |
| WP-8428-CE7 | 4 | 4 | ||||||||
| WP-8828-CE7 | 8 | |||||||||
|
|
||||||||||
|
Win-GRAF based WP-5000 series PAC
|
||||||||||
| Model | OS | Pre-Installed Software |
CPU | System Memory | Non-Volatile Memory | Storage | Ethernet Port |
USB Port | RS-232/ RS-485 |
I/O Expansion |
|---|---|---|---|---|---|---|---|---|---|---|
| WP-5238-CE7 | Windows CE 7.0 | Win-GRAF | Cortex-A8, 1.0 GHz | 512 MB DDR3 SDRAM | 64 KB FRAM | 256 MB Flash and 4 GB microSD | 1 | 1 | 4 | XV-board (Note) |
| Note: The I/O Expansion Bus can mount one XV-board only. | ||||||||||
|
|
|||||||||
|
Win-GRAF based RPAC
|
|||||||||
| Model | OS | Pre-Installed Software |
CPU | System Memory | Non-Volatile Memory | Storage | Ethernet Port |
USB Port | RS-232/ RS-485 |
|---|---|---|---|---|---|---|---|---|---|
| RPAC-2658M | Linux 4.1.15 | Win-GRAF | Quad core Cortex-A9,1 GHz | 1GB DDR3 RAM | 64 KB FRAM | 8GB eMMC Flash and 4 GB microSD | 3 | 2 | 4 |
|
|
|||||||||||
|
Win-GRAF Based ViewPAC
|
|||||||||||
| Model | OS | Pre-Installed Software |
CPU | System Memory | Non-Volatile Memory | Storage | VGA Resolution | Ethernet Port |
USB Port | RS-232/ RS-485 |
I/O Slot |
|---|---|---|---|---|---|---|---|---|---|---|---|
| VP-2208-CE7 | Windows CE 7.0 | Win-GRAF | Cortex-A8, 1.0 GHz | 512 MB DDR3 SDRAM, 256 MB Flash | 128 KB MRAM; 16 KB EEPROM | 4 GB microSD card (up to 32 GB) | 800 x 480 | 1 | 2 | 2 | – |
| VP-3208-CE7 | 800 x 600 | 3 | |||||||||
| VP-4208-CE7 | |||||||||||
| VP-5208-CE7 | |||||||||||
| VP-6208-CE7 | 1024 x 768 | ||||||||||
| VP-1238-CE7 | 640 x 480 | 1 | 2 | 3 | |||||||
| VP-4238-CE7 | 800 x 600 | 2 | |||||||||
| VP-6238-CE7 | 1024 x 768 | ||||||||||
-
Redundancy
| Model | WP-9×28-CE7 | XP-8×38-CE6 | WP-8×28-CE7 | WP-5238-CE7 | VP-x208-CE7 | VP-x238-CE7 | RPAC-2658M |
|---|---|---|---|---|---|---|---|
| Support | – | ![]() |
– | – | – | – | ![]() |
1. Near-Field RedundancyRefer to Win-GRAF User Manual: Chapter 16 |
|||||||
![]() |
|||||||
2. Far-Field RedundancyRefer to Win-GRAF User Manual: Chapter 16 |
|||||||
![]() |
|||||||
-
eLogger HMI
| Model | WP-9×28-CE7 | XP-8×38-CE6 | WP-8×28-CE7 | WP-5238-CE7 | VP-x208-CE7 | VP-x238-CE7 | RPAC-2658M |
|---|---|---|---|---|---|---|---|
| Support | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
– |
| eLogger is a free-of-charge and easy-to-use HMI software platform developed by ICP DAS. It can be used to design the Local HMI and the Web Server HMI for remotely controlling the PAC through a web browser on your PC or cell phone.
Refer to Win-GRAF User Manual: Chapter 15 |
|||||||
![]() |
|||||||
-
On-Line Change
| Model | WP-9×28-CE7 | XP-8×38-CE6 | WP-8×28-CE7 | WP-5238-CE7 | VP-x208-CE7 | VP-x238-CE7 | RPAC-2658M |
|---|---|---|---|---|---|---|---|
| Support | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
| Replace the current running project to a new modified one without stopping the project.
Refer to Win-GRAF or RPAC User Manual: Chapter 9 |
|||||||
![]() |
|||||||
-
Schedule Control
| Model | WP-9×28-CE7 | XP-8×38-CE6 | WP-8×28-CE7 | WP-5238-CE7 | VP-x208-CE7 | VP-x238-CE7 | RPAC-2658M |
|---|---|---|---|---|---|---|---|
| Support | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
| * One PAC can control up to 10 Targets (devices) with specified schedule configurations. * One BOOL variable, one DINT variable, and one REAL variable can be used for each schedule Target.Refer to Win-GRAF User Manual: Chapter 17 Refer to RPAC User Manual: Chapter 15 |
|||||||
![]() |
|||||||
-
Create Your Own Functions and Function Blocks
| Model | WP-9×28-CE7 | XP-8×38-CE6 | WP-8×28-CE7 | WP-5238-CE7 | VP-x208-CE7 | VP-x238-CE7 | RPAC-2658M |
|---|---|---|---|---|---|---|---|
| Support | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
– |
| * For some reason, like business protection or the integration of custom protocol for products. Users can develop their own functions and function blocks by using VS 2008 and then use these functions (blocks) in the Win-GRAF project.
Refer to Win-GRAF User Manual: Chapter 18 |
|||||||
![]() |
|||||||
-
Modbus Master/Slave Protocol
| Model | WP-9×28-CE7 | XP-8×38-CE6 | WP-8×28-CE7 | WP-5238-CE7 | VP-x208-CE7 | VP-x238-CE7 | RPAC-2658M |
|---|---|---|---|---|---|---|---|
| Support | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
* The following Modbus protocols are supported for Win-GRAF PACs.
Refer to Win-GRAF or RPAC User Manual: Chapter 3 and Chapter 5 |
|||||||
![]() |
|||||||
-
DCON Remote I/O & Local I/O
| Model | WP-9×28-CE7 | XP-8×38-CE6 | WP-8×28-CE7 | WP-5238-CE7 | VP-x208-CE7 | VP-x238-CE7 | RPAC-2658M |
|---|---|---|---|---|---|---|---|
| Support | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
| * Win-GRAF PACs support to connect DCON remote I/O modules via RS-485 port.
Local I/O modules: Refer to Win-GRAF or RPAC User Manual: Chapter 8 |
|||||||
![]() |
|||||||
-
PID Control
| Model | WP-9×28-CE7 | XP-8×38-CE6 | WP-8×28-CE7 | WP-5238-CE7 | VP-x208-CE7 | VP-x238-CE7 | RPAC-2658M |
|---|---|---|---|---|---|---|---|
| Support | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
| * A single Win-GRAF PAC supports 200 PID control.
Refer to Win-GRAF User Manual: Chapter 12 (PID Demo) |
|||||||
![]() |
|||||||