Thiết bị đo điện 1 pha 1P4W giao tiếp RS-485 Modbus RTU ICP DAS PM-3114-160
Features
- True RMS Power Measurements
- Energy Analysis for 1P2W, 1P4W
- Current Measurements Up to 200 A with Different CT Ratio
- Voltage Measurements Up to 300 V
- Clip-on CT for Easy Installation
- W Accuracy Better than 1% (PF=1)
- Supports RS-485, Ethernet or CAN bus Interface
- Supports Modbus RTU, Modbus TCP or CANopen Protocol
- Supports 2 Power Relay Output (Form A)
Introduction
ICP DAS brings the most powerful, cost-effective, advanced Smart Power Meters PM-3000 series that gives you access to real-time electric usage for single-phase power measurement. With its high accuracy (<1%, PF=1 ), the PM-3000 series can be applied to both low voltage primary side and/or medium/high voltage secondary side and enables the users to obtain reliable and accurate energy consumption readings from the monitored equipments in real time under operation. These compact size and cost-effective power meters are equipped with revolutionary wired clip-on CT (various types, support input current up to 200 A). It operates over a wide input voltages range 10 ~ 300 VAC which allows worldwide compatibility. And with 2 channels relay outputs, it can be linked with sirens or lightings for alarm messages. It also supports Modbus RTU, Modbus TCP or CAN bus protocols for easy integration.
Specifications
| Model | PM-3112 | PM-3114 | PM-3112-MTCP | PM-3114-MTCP | PM-3112-CPS | PM-3114-CPS | |
| AC Power Measurement | |||||||
| Wiring | 1P2W-2CT | 1P4W-4CT | 1P2W-2CT | 1P4W-4CT | 1P2W-2CT | 1P4W-4CT | |
| Input Voltage | 10 ~ 300 V | ||||||
| Input Current | CT Φ10 mm (60 A); CTΦ16 mm (100 A); CTΦ24 mm (200 A) | ||||||
| Input Frequency | 50/60 Hz | ||||||
| W Accuracy | Better than 1% (PF=1) | ||||||
| Starting Current | >0.03A ( 60A ), >0.05A (100A ), >0.09A( 200A ) | ||||||
| Power Parameter Measurement | True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF) | ||||||
| Data Update Rate | 1 Second | ||||||
| Communication | |||||||
| RS-485 | Protocol | Modbus-RTU | – | – | |||
| Baud rate | 9600,19200 (default), 38400, 115200; DIP Switch Selectable |
– | – | ||||
| Data format | N,8,1 | – | – | ||||
| Isolation | 2500 VDC | – | – | ||||
| Ethernet | Protocol | – | Modbus TCP | – | |||
| CAN Bus | Protocol | – | – | CAN Bus and CANopen | |||
| Baud rate | – | – | 125 k (default), 250 k, 500 k, 1 M; DIP Switch Selectable |
||||
| Isolation | – | 2500 VDC | |||||
| Alarm Output | |||||||
| Power Relay | Form A (Normal Open) x 2; Relay Contact Voltage Range: 5 A @ 250 VAC (47 ~ 63Hz), 5 A @ 30 VDC | ||||||
| Power | |||||||
| Input Range | +10 ~ 30 VDC | +12 ~ 48 VDC | +10 ~ 30 VDC | ||||
| Power Consumption | 2 W | ||||||
| Mechanical | |||||||
| Casing | Plastic (Flammability UL 94V-0) | ||||||
| Dimensions (W x L x H) | 127 mm x 105 mm x 33 mm | ||||||
| Module Installation | DIN-Rail Mounting | ||||||
| CT Installation | Clip-On | ||||||
| Environment | |||||||
| Operating Temperature | -10 ~ +70 °C | ||||||
| Storage Temperature | -25 ~ +80 °C | ||||||
| Ambient Relative Humidity | 10% ~ 90% RH, Non-condensing | ||||||
Ordering Information
| RS-485 Interface (NEW) | |
| PM-3112-100 | Modbus RTU; 2 loops single-phase Power Meter with 2 CTs (60 A) |
| PM-3112-160 | Modbus RTU; 2 loops single-phase Power Meter with 2 CTs (100 A) |
| PM-3112-240 | Modbus RTU; 2 loops single-phase Power Meter with 2 CTs (200 A) |
| PM-3114-100 | Modbus RTU, 4 loops single-phase power meter (60 A) |
| PM-3114-160 | Modbus RTU, 4 loops single-phase power meter (100 A) |
| PM-3114-240 | Modbus RTU, 4 loops single-phase power meter (200 A) |
| Ethernet Interface (NEW) | |
| PM-3112-100-MTCP | Modbus TCP; 2 loops single-phase Power Meter with 2 CTs (60 A) |
| PM-3112-160-MTCP | Modbus TCP; 2 loops single-phase Power Meter with 2 CTs (100 A) |
| PM-3112-240-MTCP | Modbus TCP; 2 loops single-phase Power Meter with 2 CTs (200 A) |
| PM-3114-100-MTCP | Modbus TCP, 4 loops single-phase power meter (60 A) |
| PM-3114-160-MTCP | Modbus TCP, 4 loops single-phase power meter (100 A) |
| PM-3114-240-MTCP | Modbus TCP, 4 loops single-phase power meter (200 A) |
| CANopen Interface (NEW) | |
| PM-3112-100-CPS | CANopen; 2 loops single-phase Power Meter with 2 CTs (60 A) |
| PM-3112-160-CPS | CANopen; 2 loops single-phase Power Meter with 2 CTs (100 A) |
| PM-3112-240-CPS | CANopen; 2 loops single-phase Power Meter with 2 CTs (200 A) |
| PM-3114-100-CPS | CANOpen, 4 loops single-phase power meter (60 A) |
| PM-3114-160-CPS | CANOpen, 4 loops single-phase power meter (100 A) |