Bộ sạc ắc quy tự động chức năng UPS MCTT-AD-155C 156.5W, 54V(48V), 2.7A
155W Single Output with Battery Charger (UPS Function) AD-155 series
Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Battery low and battery polarity protection
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 45KHz
1 years warranty
| SPECIFICATION | ||||||
| MODEL |
AD-155A |
AD-155B |
AD-155C |
|||
| OUTPUT | ||||||
| Outputnumber |
CH1 |
CH2 |
CH1 |
CH2 |
CH1 |
CH2 |
| DC voltage |
13.8V |
13.3V |
27.6V |
27.1V |
54V |
53.5V |
| Rated Current |
10.5A |
0.5A |
5A |
0.5A |
2.7A |
0.2A |
| Current Range |
0~11.5A |
0-0.5A |
0~5.5A |
0-0.5A |
0-2.7A |
0-0.5A |
| Rated Power |
151.55W |
151.55W |
156.5W |
|||
| Ripple&Noise |
100mVp-p |
——– |
150mVp-p |
——– |
240mVp-p |
——– |
| Voltage Adj.Range |
CH1:12~14.5V |
CH1:24~29V |
CH1:48-58V |
|||
| Voltage Tolerance |
±2.0% |
——– |
±1.0% |
——– |
±1.0% |
——– |
| Line Regulation |
±0.5% |
——– |
±0.5% |
——– |
±0.5% |
——– |
| Load Regulation |
±0.5% |
——– |
±0.5% |
——– |
±0.5% |
——– |
| Setup,Rise Time | 1000ms, 90ms/230VAC 2000ms, 90ms/115VAC at full load | |||||
| Hold UpTime | 24ms/230VAC 20ms/115VAC at full load | |||||
|
INPUT |
||||||
|
Voltage Range |
88~264VAC47~63Hz; 124~370VDC |
|||||
|
AC Current |
2.5A/115VAC 1.5A/230VAC |
|||||
| Efficiency |
80% |
84% |
84% |
|||
| Inrush Current | Coldstart 20A/115VAC 40A/230VAC | |||||
| Leakage Current | <1mA /240VAC | |||||
| PROTECTION | ||||||
| Over Load | CH1:105 ~ 135% CH2:0.51 ~ 0.9A rated output power | |||||
| Protection type:AC Charging Mode:Hiccup mode,recovers automatically after fault condition is removed UPS Mode:Protected by internal fuse | ||||||
| Over Voltage |
CH1:15.87~18.63V |
CH1:31.74~37.26V |
CH1:62.1 ~ 72.9V |
|||
| Protection type:Shut down o/p voltage, re-power on to recover | ||||||
| Battery Low | 10V±0.8V | 19.5V(+1.5V,-1V ) | 39V±2V | |||
| ENVIRONMENT | ||||||
| Working Temp. | -10~+60℃(Refer to“Derating Curve”) | |||||
| Working Humidity | 20~90%RH non-condensing | |||||
| Storage Temp.,Humidity | -20~+85℃,10~95%RH | |||||
| Temp.Coefficient | ±0.03%/ ℃(0~50℃ ) | |||||
| Vibration | 10~500Hz,2G10min./1cycle,60min.each along X, Y,Z axes | |||||
| SAFETY &EMC | ||||||
| Safety Standards | UL60950-1, TUV EN60950-1 | |||||
| Withstand Voltage | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||
| Isolation Resistance | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC /25℃ /70%RH | |||||
| EMC Emission | Compliance to EN55022(CISPR22) Class B, EN61000-3-2,-3 | |||||
| EMC Immunity | Compliance to EN61000-4-2,3,4,5,6,8,11,EN55024,light industry level, criteria A | |||||
| OTHERS | ||||||
| Dimension | 199*110*50mm (L*W*H) | |||||
| Weight | 0.72Kg | |||||
| Packing | 20pcs/15.5KG | |||||
| NOTE | ||||||
| 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meetsEMC directives. |
||||||