Bộ đổi nguồn tổ ong MCTT-LRS-100-12 100W, 12VDC, 8.5A
MCTT-LRS-100 series is a 100W single output enclosed type power supply with 30mm of low profile design. Adopting the full range 85~264VAC input, the entire series provides an output voltage line of 5V, 12V, 24V, 36V and 48V.
In addition to the high efficiency up to 91%, the design of metallic mesh case enhances the heat dissipation of MCTT-LRS-100 that the whole series operates from -30 ~ 70℃ under air convection without a fan. Delivering an extremely low no load power consumption (less than 0.3W), it allows the end system to easily meet the worldwide energy requirement. MCTT-LRS-100 has the complete protection functions and 5G anti-vibration capability; it is complied with the international safety regulations such as UL60950-1, IEC/EN60950-1, IEC/EN61558-2-16, IEC/EN60335-1 and CCC GB4943. MCTT-LRS-100 series serves as a high price-to-performance power supply solution for various industrial applications.
Features:
- Universal AC input/ Full range
- Withstand 300VAC surge input for 5 second
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- Miniature size and 1U low profile
- LED indicator for power on
- 100% full load burn-in test
- High operating temperature up to 70℃
- High efficiency, long life and high reliability
- 1 years warranty
Specifications
| Model | MCTT-LRS-100-5 | MCTT-LRS-100-12 | MCTT-LRS-100-24 | MCTT-LRS-100-36 | MCTT-LRS-100-48 | |
| Output | DC Voltage | 5V | 12V | 24V | 36V | 48V |
| Rated Current | 18A | 8.5A | 4.5A | 2.8A | 2.3A | |
| Current Range | 0~18A | 0~8.5A | 0~4.5A | 0~2.8A | 0~2.3A | |
| Rated Power | 90W | 102W | 108W | 100.8W | 110.4W | |
| Ripple & Noise | 100mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
| Voltage Adj. Range | 4.5~5.5V | 10~ 13.8V | 21.6~28.8V | 32~39.6V | 43.2~52.8V | |
| Voltage Tolerance | ±2% | ±1% | ±1% | ±1% | ±1% | |
| Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
| Load Regulation | ±1% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
| Setup, Rise Time | 500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load | |||||
| Hold Up Time | 55ms/230VAC 10ms/115VAC at full load | |||||
| Input | Voltage Range | 85 ~ 264VAC 120~373VDC | ||||
| Frequency Range | 47 ~ 63Hz | |||||
| Efficiency | 86% | 88% | 90% | 90.5% | 91% | |
| AC Current | 1.9A/115VAC 1.2A/230VAC | |||||
| Inrush Current | Cold start, 50A at 230VAC | |||||
| Leakage Current | <0.75mA / 240VAC | |||||
| Protection | Over Load | 110 ~ 150% rated output power | ||||
| Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||
| Over Voltage | 115%~135% rated output voltage | |||||
| Protection type: Shut down and latch off o/p voltage, re-power on to recover | ||||||
| Environment | Working Temp. | -30 ~ +70℃ (Refer to “Derating Curve”) |
| Working Humidity | 20 ~ 90% RH non-condensing | |
| Storage Temp., Humidity | -40 ~ +85℃, 10 ~ 95% RH | |
| Temp. Coefficient | ±0.03%/℃ (0 ~ 50℃) | |
| Vibration | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | |
| Safety | Safety Standards | UL60950-1, IEC/EN60950-1, IEC/EN61558-2-16, IEC/EN60335-1, CCC GB4943 approved |
| Withstand Voltage | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC,1minute | |
| EMC standards | EN55022 class B, EN55014, EN61000-3-2,3, EN61000-4,2,3,4,5,6,8,11, GB9254 | |
| Others | Dimension | 129*97*30mm (L*W*H) |
| Weight | 0.34Kg | |
| Connection | 7P/9.5mm pitch terminal block | |
| Note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. |
|