Bộ đổi nguồn tổ ong MCTT-LRS-350-15 350W, 15VDC, 23.2A




Features:
- AC input range selectable by switch
- Withstand 300VAC surge input for 5 second
- Protections: Short circuit / Overload / Over voltage/ Over temperature
- Forced air cooling by built-in DC fan
- Built-in cooling Fan ON-OFF control
- LED indicator for power on
- 100% full load burn-in test
- High operating temperature up to 70℃
- High efficiency, long life and high reliability
| SPECIFICATION | ||||||||||||||
| OUTPUT | ||||||||||||||
| Model |
MCTT-LRS-350-3.3 |
MCTT-LRS-350-5 |
MCTT-LRS-350-12 |
MCTT-LRS-350-15 |
MCTT-LRS-350-24 |
MCTT-LRS-350-36 |
MCTT-LRS-350-48 |
|||||||
| DC Voltage |
3.3V |
5V |
12V |
15V |
24V |
36V |
48V |
|||||||
| Rated Current |
60A |
60A |
29A |
23.2A |
14.6A |
9.7A |
7.3A |
|||||||
| Current Range |
0~60A |
0~60A |
0~29A |
0~23.2A |
0~14.6A |
0~9.7A |
0~7.3A |
|||||||
| Rated Power |
198W |
300W |
348W |
348W |
350.4W |
349.2W |
350.4W |
|||||||
| Ripple&Noise |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
200mVp-p |
200mVp-p |
|||||||
| VoltageAdj. Range |
2.97~3.6V |
4.5 ~ 5.5V |
10~ 13.8V |
13.5~18V |
21.6~28.8V |
32.4~39.6V |
43.2~52.8V |
|||||||
| Voltage Tolerance |
±4.0% |
±3.0% |
±1.5% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
|||||||
| Line Regulation |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|||||||
| Load Regulation |
±2.5% |
±2.0% |
±1.0% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|||||||
| Setup,Rise Time | 1300ms, 50ms/230VAC 1300ms, 50ms/115VAC at full load | |||||||||||||
| Hold Up Time | 16ms/230VAC 12ms/115VAC at full load | |||||||||||||
| INPUT | ||||||||||||||
| Voltage Range | 90 ~ 132VAC / 180 ~ 264VAC selected by switch 254 ~ 370VDC (switch on 230VAC) | |||||||||||||
| Frequency Range | 47 ~ 63Hz | |||||||||||||
| Efficiency |
79.5% |
83.5% |
85% |
86% |
88% |
88.5% |
89% |
|||||||
| AC Current | 6.8A/115VAC 3.4A/230VAC | |||||||||||||
| Inrush Current | 60A/115VAC 60A/230VAC | |||||||||||||
|
Leakage Current |
<2mA / 240VAC | |||||||||||||
| PROTECTION | ||||||||||||||
| Over Load | 110 ~ 140% rated output power | |||||||||||||
| Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||||||||||
| Over Voltage |
3.8~4.45V |
5.75~6.75V |
13.8~16.2V |
18~21V |
28.8~33.6V |
41.4~46.8V |
55.2~64.8V |
|||||||
| Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||||||||||
| Over temperature | Hiccup mode, recovers automatically after fault condition is removed | |||||||||||||
| ENVIRONMENT | ||||||||||||||
| Working Temp. | -20 ~ +70℃ (Refer to “derating curve”) | |||||||||||||
| Working Humidity | 20 ~ 90% RH non-condensing | |||||||||||||
| StorageTemp., Humidity | -40 ~ +85℃, 10 ~ 95% RH | |||||||||||||
| Temp. Coefficient | ±0.03%/℃ (0 ~ 50℃) | |||||||||||||
| Vibration | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | |||||||||||||
| SAFETY | ||||||||||||||
| Safety Standards | UL60950-1 approved | |||||||||||||
| Withstand Voltage | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||||||||||||
| Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃ / 70% RH | |||||||||||||
| OTHERS | ||||||||||||||
| Dimension | 215*115*30mm (L*W*H) | |||||||||||||
| Weight | 0.76Kg | |||||||||||||
| Packing | 15pcs/carton/12.4kg/0.78CUFT | |||||||||||||
| NOTE | ||||||||||||||
| 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meetsEMC directives. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. |
||||||||||||||