Bộ đổi nguồn tổ ong MCTT-S-60-24 60W, 24VDC, 2.5A
60W Single Output Switching Power Supply S-60 series
Features:
High efficiency, high reliability
Universal AC input / Full range
100% full load burn-in test
Protections: Short circuit / Over load / Over voltage
Cooling by free air convection
Fixed switching frequency at 50KHz
1 years warranty
| SPECIFICATIONS | |||||
| OUTPUT | |||||
| Model |
S-60-5 |
S-60-12 |
S-60-15 |
S-60-24 |
S-60-48 |
| DC Voltage |
5V |
12V |
15V |
24V |
48V |
| Rated Current |
12A |
5A |
4A |
2.5A |
1.3A |
| Current Range |
0-12A |
0-5A |
0-4A |
0-2.5A |
0-1.3A |
| Rated Power |
60W |
60W |
60W |
60W |
62W |
| Ripple & Noise |
120mVp-p |
120mVp-p |
150mVp-p |
150mVp-p |
200mVp-p |
| Voltage Adj. Range |
-5%, +10% |
±10% |
±10% |
±10% |
±10% |
| Voltage Tolerance |
±2% |
±1% |
±1% |
±1% |
±1% |
| Setup, Rise, Hold Up Time | 800ms,50ms,10ms/115VAC 300ms,50ms,80ms/230VAC at full load | ||||
| INPUT | |||||
| Voltage Range |
85~132VAC/170~264VAC selected by switch 47~63Hz; 240~370VDC |
||||
| AC Current | 2A/115V 1A/230V | ||||
| Efficiency |
73% |
76% |
77% |
79% |
80% |
| Inrush Current | Cold start 30A/115VAC 60A/230VAC | ||||
| Leakage Current | <3.5mA/240VAC | ||||
| PROTECTION | |||||
| Over Load | 105%~150% | ||||
| Protection type: Fold back current limiting, recovers automatically after fault condition is removed. | |||||
| Over Voltage | 115%~135% | ||||
| Protection type: hiccup mode, recovers automatically after fault condition is removed. | |||||
| ENVIRONMENT | |||||
| Working Temp., Humidity | -10℃~+60℃; 20%~90%RH | ||||
| Storage Temp., Humidity | -20℃~+85℃; 10%~95%RH | ||||
| Vibration | 10~500Hz, 2G 10min./1cycle,period for 60min, each long X, Y, Z, axes | ||||
| SAFETY | |||||
| Withstand Voltage | I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | ||||
| Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | ||||
| STANDARD | |||||
| Safety Standard | Design refer to UL1012, UL1950, TUV EN60950 | ||||
| EMC Standard | Design refer to EN55022, EN61000-3-2, -3, EN61000-4-2, 3, 4, 5, 6, 8, 11; ENV50204, EN55024 | ||||
| OTHERS | |||||
| Dimension | 159*97*38mm(L*W*H) | ||||
| Weight | 0.51Kg | ||||
| Packing | 24pcs/13.1Kg/0.7CUFT | ||||
| NOTE | |||||
| 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |
|||||