Bộ đổi nguồn tổ ong MCTT-NES-25-15 25W, 15VDC, 1.7A
25W Single Output Switching Power Supply NES-25 series
Features:
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
1 year warranty
| SPECIFICATION | ||||||
| OUTPUT | ||||||
| Model |
NES-25-5 |
NES-25-12 |
NES-25-15 |
NES-25-24 |
NES-25-48 |
|
| DC Voltage |
5V |
12V |
15V |
24V |
48V |
|
| Rated Current |
5A |
2.1A |
1.7A |
1.1A |
0.57A |
|
| Current Range |
0 ~ 5A |
0 ~ 2.1A |
0 ~ 1.7A |
0 ~ 1.1A |
0 ~ 0.57A |
|
| Rated Power |
25W |
25.2W |
25.5W |
26.4W |
27.36W |
|
| Ripple&Noise |
80mVp-p |
120mVp-p |
150mVp-p |
200mVp-p |
240mVp-p |
|
| Voltage Adj. Range |
4.75~5.5V |
10.8~13.2V |
13.5~16.5V |
21.6~26.4V |
43.2~52.8V |
|
| Voltage Tolerance |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
|
| Line Regulation |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
| Load Regulation |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
| Setup,Rise Time | 500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load | |||||
| Hold Up Time | 50ms/230VAC 10ms/115VAC at full load | |||||
| INPUT | ||||||
| Voltage Range | 85 ~ 264VAC 120 ~ 370VDC | |||||
| Frequency Range | 47 ~ 63Hz | |||||
| Efficiency |
78% |
83% |
84% |
86% |
86% |
|
| AC Current | 0.55A/115VAC 0.35A/230VAC | |||||
| Inrush Current | Cold Start 45A | |||||
| Leakage Current | <2mA / 240VAC | |||||
| PROTECTION | ||||||
| Over Load | 110 ~ 150% rated output power | |||||
| Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||
| Over Voltage |
5.75~6.75V |
13.8~16.2V |
17.25~20.25V |
27.6~32.4V |
55.2~64.8V |
|
| Protection type: Shut down o/p voltage, re-power on to recover | ||||||
| ENVIRONMENT | ||||||
| Working Temp. | -20 ~ +60℃ (Refer to “Derating Curve”) | |||||
| Working Humidity | 20 ~ 90% RH non-condensing | |||||
| StorageTemp., Humidity | -40 ~ +85℃, 10 ~ 95% RH | |||||
| Temp. Coefficient | ±0.03%/℃ (0 ~ 45℃) | |||||
| Vibration | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |||||
| SAFETY &EMC | ||||||
| Safety Standards | Design refer to UL60950-1, CB(IEC60950-1),CCC GB4943 | |||||
| Withstand Voltage | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||
| Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃ / 70% RH | |||||
| EMC Emission | Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 | |||||
| EMC Immunity | Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, EN55024, EN61000-6-1, light industry level, criteria A | |||||
| OTHERS | ||||||
| Dimension | 99*82*35mm (L*W*H) | |||||
| Weight | 0.3Kg | |||||
| Packing | 45pcs/14.5Kg/0.66CUFT | |||||
| NOTE | ||||||
| 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meetsEMC directives. |
||||||