Bộ đổi nguồn Din-Rail MCTT-MDR-40-24 40W, 24VDC, 1.7A





Features:
- Universal AC input/ full range
- Protections: Short circuit/ Over load/ Over voltage
- Cooling by free air convection
- Can be installed on DIN rail TS-35/7.5 or 15
- isolation classⅡ
- LED indicator for power on
- 100% full load burn-in test
- 1 years warranty
| OUTPUT | ||||
| Model | MCTT-MDR-40-5 | MCTT-MDR-40-12 | MCTT-MDR-40-24 | MCTT-MDR-40-48 |
| DC Voltage | 5V | 12V | 24V | 48V |
| Rated Current | 6A | 3.33A | 1.7A | 0.83A |
| Current Range | 0~6A | 0~3.33A | 0~1.7A | 0~0.83A |
| Rated Power | 30W | 40W | 40.8W | 39.8W |
| Ripple & Noise | 80mVp-p | 120mVp-p | 150mVp-p | 200mVp-p |
| Voltage Adj. Range | 5~6V | 12~15V | 24~30V | 48~56V |
| Voltage Tolerance | ±2% | ±1% | ±1% | ±1% |
| Setup, Rise Time | 500ms,30ms/230VAC; 500ms,30ms/115VAC at full load | |||
| Hold Up Time | 50ms/230VAC; 20ms/115VAC at full load | |||
| INPUT | ||||
| Voltage Range | 85~264VAC (47~63Hz); 120~370VDC | |||
| AC Current | 1.1A/115V; 0.7A/ 230V | |||
| Efficiency | 78% | 85% | 88% | 88% |
| Inrush Current | Cold start, 30A at 115VAC, 60A at 230VAC | |||
| Leakage Current | <1mA/240VAC | |||
| PROTECTION | ||||
| Over Load | 105%~150% | |||
| Protection type: Constant current limiting, recovers automatically after fault condition is removed | ||||
| Over Voltage | 115%~135% | |||
| Protection type: Shut down o/p voltage, re-power on to recover | ||||
| Function | DC OK Signal | Relay contact rating (max.): 30V/1A resistive |
| Environment | Working Temp. | -20 ~ +70℃ (Refer to “Derating Curve”) |
| Working Humidity | 20 ~ 90% RH non-condensing | |
| Storage Temp., Humidity | -40 ~ +85℃, 10 ~ 95% RH | |
| Temp. Coefficient | ±0.03%/℃ (0 ~ 50℃) | |
| Vibration | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | |
| Safety | Safety Standards | UI508, TUV EN60950-1, UL60950-1 approved, NEC class 2 compliant |
| Withstand Voltage | I/P-O/P:3KVAC, I/P-FG:2KVAC, 1minute | |
| EMC standards | EN55022 class B, EN61000-3-2,-3, ENV50204, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level | |
| Others | Dimension | 40*90*100mm (L*W*H) |
| Weight | 0.26Kg | |
| Connection | I/P: 3 poles, O/P: 6 poles screw DIN terminal | |
| Note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. |
|
Download