Bộ đổi nguồn tổ ong MCTT-S-50-12 50W, 12VDC, 4.2A
50W Single Output Switching Power Supply S-50 series
Features:
High efficiency, high reliability, low cost
AC input range selected by switch
Protections: Short circuit/ Over load
cooling by free air convection
LED indicator for power on
Fixed switching frequency at 27KHz
1 years warranty
| SPECIFICATIONS | |||||
| OUTPUT | |||||
| Model |
S-50-5 |
S-50-12 |
S-50-15 |
S-50-24 |
S-50-48 |
| DC Voltage |
5V |
12V |
15V |
24V |
48V |
| Rated Current |
10A |
4.2A |
3.4A |
2.1A |
1A |
| Current Range |
0-10A |
0-4.2A |
0-3.4A |
0-2.1A |
0-1A |
| Rated Power |
50W |
50.4W |
51W |
50.4W |
48W |
| Ripple & Noise |
75mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
| Voltage Adj. Range |
-5%, +10% |
±10% |
±10% |
±10% |
±10% |
| Voltage Tolerance |
±2% |
±1% |
±1% |
±1% |
±1% |
| Setup, Rise, Hold Up Time | 200ms,100ms,20ms at full load | ||||
| INPUT | |||||
| Voltage Range | 85~132VAC/170~264VAC selected by switch 47~63Hz; 240~370VDC | ||||
| AC Current | 1.3A/115V 0.65A/230V | ||||
| Efficiency |
71% |
78% |
78% |
82% |
84% |
| Inrush Current | Cold start 18A/115V 36A/230V | ||||
| Leakage Current | <1mA/240VAC | ||||
| PROTECTION | |||||
| Over Load | 105%~15 0% | ||||
| Protection type: Fold back current limiting, recovers automatically after fault condition is removed | |||||
| ENVIRONMENT | |||||
| Working Temp., Humidity | -10℃~+60℃; 20%~90%RH | ||||
| Storage Temp., Humidity | -20℃~+85℃; 10%~95%RH | ||||
| Vibration | 10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes | ||||
| SAFETY | |||||
| Withstand Voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||
| Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | ||||
| STANDARD | |||||
| Safety Standard | Design refer to UL1012 | ||||
| EMC Standard | Design refer to FCC Part15 J Conduction Class B | ||||
| OTHERS | |||||
| Dimension | 159*97*38mm(L*W*H) | ||||
| Weight | 0.51Kg | ||||
| Packing | 24pcs/13.1Kg/0.7CUFT | ||||
| NOTE | |||||
| 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation |
|||||