Bộ đổi nguồn công suất cao 1500W từ 230VAC ra 12VDC Leyu SCN-1500-12
Thông số kỹ thuật
SPECIFICATIONS |
|||||
OUTPUT |
|
||||
Model |
SCN-1500-12 |
SCN-1500-24 |
SCN-1500-27 |
SCN-1500-48 |
|
DC Voltage |
12V |
24V |
27V |
48V |
|
Rated Current |
125A |
100A |
62.5A |
32A |
|
Current Range |
0-125A |
0-100A |
0-62.5A |
0-32A |
|
Rated Power |
1500W |
1500W |
1500W |
1536W |
|
Ripple & Noise |
120mVp-p |
150mVp-p |
240mVp-p |
480mVp-p |
|
Voltage Adj. Range |
10.8~13.2V |
20~26.4V |
24~30V |
41~56V |
|
Voltage Tolerance |
±5% |
±5% |
±5% |
±5% |
|
Inlet Stability |
±1% |
±1% |
±1% |
±0.5% |
|
Load Stability |
±1% |
±1% |
±1% |
±0.5% |
|
Setup,Rise,Hold UpTime | 800ms, 50ms, 16ms at full load | ||||
|
|
||||
INPUT |
|
||||
Voltage Range |
200~260 VAC47~63 Hz;290~370VDC | ||||
AC Current |
12A/230VAC |
||||
Efficiency |
83% | 84% | 85% | 87% | |
Inrush Current |
120A/230V | ||||
Leakage Current |
<3.5mA/240VAC |
||||
|
|
||||
PROTECTION |
|
||||
Over Load |
110%~135% Type:plusing hiccup shutdown Reset:auto recovery |
||||
Over Temp. |
RTH>=80 output shutdown |
||||
|
|
||||
ENVIRONMENT |
|
||||
Working Temp., Humidity |
-10℃~+60℃(Refer to output derating curve),20%~90%RH |
||||
Storage Temp., Humidity |
-20℃~+85℃, 10%~95%RH |
||||
Temp.Coefficient |
±0.03%/℃(0~50℃) |
||||
Vibration |
10~500Hz,2G 10min,/1cycle,Period for 60min,Each X.Y.X axes |
||||
|
|
||||
SAFETY |
|
||||
Withstand Voltage |
I/P-O/P: 1.5KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC |
||||
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC |
||||
|
|
||||
STANDARD |
|
||||
Safety Standard |
Design refer to UL1950,CSA22.2,IEC60950 | ||||
EMC Standard |
Design refer to FCC Part 15 Class A | ||||
|
|
||||
OTHERS |
|
||||
Dimension |
291*132*132mm(L*W*H) |
||||
Weight |
5.0Kg |
||||
NOTE
|
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |