Bộ đổi nguồn AC/DC 100W từ 220VAC sang 24VDC 4.5A Leyu LRS-100-24, Nguồn tổ ong 24V 4.5A 100W
Thông số kĩ thuật
SPECIFICATION | |||||||||||||
OUTPUT | |||||||||||||
Model |
LRS-100-3.3 |
LRS-100-5 |
LRS-100-12 |
LRS-100-15 |
LRS-100-24 |
LRS-100-36 |
LRS-100-48 |
||||||
DC Voltage |
3.3V |
5V |
12V |
15V |
24V |
36V |
48V |
||||||
Rated Current |
20A |
18A |
8.5A |
7A |
4.5A |
2.8A |
2.3A |
||||||
Current Range |
0~20A |
0~18A |
0~8.5A |
0~7A |
0~4.5A |
0~2.8A |
0~2.3A |
||||||
Rated Power |
66W |
90W |
102W |
105W |
108W |
100.8W |
110.4W |
||||||
Ripple&Noise |
100mVp-p |
100mVp-p |
120mVp-p |
120mVp-p |
150mVp-p |
200mVp-p |
200mVp-p |
||||||
VoltageAdj. Range |
2.97~3.6V |
4.5 ~ 5.5V |
10.2~ 13.8V |
13.5~18V |
21.6~28.8V |
32.4~39.6V |
43.2~52.8V |
||||||
Voltage Tolerance |
±3.0% |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
||||||
Line Regulation |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
||||||
Load Regulation |
±2.0% |
±1.0% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
||||||
Setup,Rise Time | 500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load | ||||||||||||
Hold Up Time | 55ms/230VAC 10ms/115VAC at full load | ||||||||||||
INPUT | |||||||||||||
Voltage Range | 85 ~ 264VAC 120 ~ 373VDC | ||||||||||||
Frequency Range | 47 ~ 63Hz | ||||||||||||
Efficiency |
84.5% |
86% |
88% |
88.5% |
90% |
90.5% |
91% |
||||||
AC Current | 1.9A/115VAC 1.2A/230VAC | ||||||||||||
Inrush Current | Cold start 50A/230VAC | ||||||||||||
Leakage Current |
<0.75mA / 240VAC | ||||||||||||
PROTECTION | |||||||||||||
Over Load | 110 ~ 150% rated output power | ||||||||||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | |||||||||||||
Over Voltage |
3.8~4.45V |
5.75~6.75V |
13.8~16.2V |
18.75~21.75V |
28.8~33.6V |
41.4~48.6V |
55.2~64.8V |
||||||
Protection type: shut down o/p voltage, re-power on to recover | |||||||||||||
ENVIRONMENT | |||||||||||||
Working Temp. | -30 ~ +70℃ (Refer to “derating curve”) | ||||||||||||
Working Humidity | 20 ~ 90% RH non-condensing | ||||||||||||
StorageTemp., Humidity | -40 ~ +85℃, 10 ~ 95% RH | ||||||||||||
Temp. Coefficient | ±0.03%/℃ (0 ~ 50℃) | ||||||||||||
Vibration | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | ||||||||||||
SAFETY &EMC | |||||||||||||
Safety Standards | UL60950-1, TUV EN60950-1, EN60335-1/-2-16, CCC GB4943 approved | ||||||||||||
Withstand Voltage | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC | ||||||||||||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃ / 70% RH | ||||||||||||
EMC Emission | Compliance to EN55022(CISPR22), GB9254 CLASS B, EN55014 EN 61000-3-2,-3 | ||||||||||||
EMC Immunity | Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2(EN50082-2), heavy industry level, criteria A | ||||||||||||
OTHERS | |||||||||||||
Dimension | 129*97*30mm (L*W*H) | ||||||||||||
Weight | 0.34Kg | ||||||||||||
Packing | 40pcs/carton/14.6kg/0.92CUFT |