Bộ sạc tự động cho ắc quy trong UPS 155W 3 kênh đầu ra 5V – 12V – 24V- 48V Leyu ADD-155
Thông số kĩ thuật
SPECIFICATION | ||||||||||||
MODEL |
ADD-155A |
ADD-155B |
ADD-155C |
|||||||||
OUTPUT |
|
|
|
|||||||||
Outputnumber |
CH1 |
CH2 |
CH3 |
CH1 |
CH2 |
CH3 |
CH1 |
CH2 |
CH3 |
|||
DC voltage |
13.8V |
5V |
13.3V |
27.6V |
5V |
27.1V |
54 V |
5 V |
53.5 V |
|||
Rated Current |
9.5A |
3A |
0.5A |
3A |
3A |
0.5A |
0.2A |
4.5A |
2.3A |
|||
Current Range |
0~10.5A |
0~3A |
——– |
0~5A |
0~3A |
——— |
0~2.5A |
0~3A |
——— |
|||
Rated Power |
152.75W |
152.75W |
149.9W |
|||||||||
Ripple&Noise |
150mVp-p |
100mVp-p |
——– |
200mVp-p |
100mVp-p |
——- |
200mVp-p |
100mVp-p |
——– |
|||
Voltage Adj.Range |
CH1:12~14.5V |
CH1:24~29V |
|
|||||||||
Voltage Tolerance |
±2.1% |
±0.5% |
——– |
±1.0% |
±0.5% |
——– |
±1.0% |
±5.0% |
——– |
|||
Line Regulation |
±1.0% |
±2.0% |
——– |
±1.0% |
±2.0% |
——– |
±1.0% |
±0.5% |
——– |
|||
Load Regulation |
±1.0% |
±3.0% |
——– |
±1.0% |
±3.0% |
——– |
±1.0% |
±2.0% |
——– |
|||
Setup,Rise Time | 1000ms, 90ms/230VAC 2000ms, 90ms/115VAC at full load | |||||||||||
Hold UpTime | 24ms/230VAC 20ms/115VAC at full load | |||||||||||
INPUT | ||||||||||||
Voltage Range | 88~264VAC47~63Hz; 124~370VDC | |||||||||||
AC Current | 2.5A/115VAC 1.5A/230VAC | |||||||||||
Efficiency |
78% |
81% |
||||||||||
Inrush Current | Coldstart 20A/115VAC 40A/230VAC | |||||||||||
Leakage Current | <1mA /240VAC | |||||||||||
PROTECTION | ||||||||||||
Over Load | CH1,CH2:105 ~ 135% CH3:0.51 ~ 0.9Arated output power | |||||||||||
Protection type:AC Charging Mode:Hiccup mode,recovers automatically after fault condition is removed UPS Mode:Protected by internal fuse | ||||||||||||
Over Voltage |
CH1:15.87~18.63V |
CH1:31.74~37.26V |
CH1:62.1~72.9V |
|||||||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||||||||
Battery Low |
10V±0.8V |
19.5V±1.5V |
39V±2V |
|||||||||
ENVIRONMENT | ||||||||||||
Working Temp. | -10~+60℃(Refer to“Derating Curve”) | |||||||||||
Working Humidity | 20~90%RH non-condensing | |||||||||||
Storage Temp.,Humidity | -20~+85℃,10~95%RH | |||||||||||
Temp.Coefficient | ±0.03%/ ℃(0~50℃ )on CH1 output | |||||||||||
Vibration | 10~500Hz,2G10min./1cycle,60min.each along X, Y,Z axes | |||||||||||
SAFETY &EMC | ||||||||||||
Safety Standards | Design refer to UL60950-1, TUV EN60950-1 | |||||||||||
Withstand Voltage | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||||||||
Isolation Resistance | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC /25℃ /70%RH | |||||||||||
EMC Emission | Compliance to EN55022(CISPR22) Class B, EN61000-3-2,-3 | |||||||||||
EMC Immunity | Compliance to EN61000-4-2,3,4,5,6,8,11,EN55024,light industry level, criteria A | |||||||||||
OTHERS | ||||||||||||
Dimension | 119*11*50mm(L*W*H) | |||||||||||
Weight | 1Kg | |||||||||||
Packing | 20pcs/12.6Kg/0.75CUFT | |||||||||||
NOTE | ||||||||||||
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meetsEMC directives. |